APPENDIX A – CONNECTOR PINOUT
ENG
Axel Technology srl
www.axeltechnology.com
30.3.1 EXAMPLE OF ACTIVATION OF INPUT 1 BY CLEAN CONTACT
To activate INPUT 1 on the Opto INPUT interface, permamently shortcut pin 9 and 1. The external switch will be
connected across pins 15 and 6.
30.3.2 EXAMPLE OF ACTIVATION OF INPUT 1 BY TTL
Input
1
DB-15p
FEMALE
1K2
+12V
1
9
15
8
INTERNAL
Input
5
Input
4
Input
2
Input
3
DB-15p
MALE
470
GND
1
9
15
8
EXTERNAL
Apply an external TTL signal through a 470 Ohm
carbon resistor to the photodiode 1 (pins 6 and 1). Max current allowed:
10 mA. Nominal: 5 mA.
For activation of TA, TP and M/S services please refer to Chapter 3.9 of this manual, AS THEY NEED A SOFTWARE
ACTIVATION IN ADDITION.
Input
1
DB-15p
FEMALE
1K2 Ohm
+12V
1
9
15
8
INTERNAL
Input
5
Input
4
Input
2
Input
3
DB-15p
MALE
1
9
15
8
EXTERNAL
Comments to this Manuals